· Run‑in: 4 hours at 20% rated speed, check for powder release.· Sudden vibration increase (acceleration >10 g) indicates unstable cage wear.· Correction: multiply calculated speed by 0.9 (oil lubrication) or 0.8 (grease lubrication).