· Empirical assembly clearance: at room temperature, guide clearance 0.02-0.04 mm larger than for steel cages.· If vibration spectrum shows half‑frequency whirl, reduce speed by 10% or increase oil flow.· Finite element analysis well established – thermal and centrifugal stresses can be accurately calculated.· Rotordynamic models can predict cage whirl stability.